Schlage Electronics CTE-MTB11 CTE ENGAGE Single Door Controller with Mobile Enabled Multi-Tech Mullion Reader Kit, Black
Enables around the door solution with ENGAGE functionality
Built-in Bluetooth® and Wi-Fi®
Complete with Schlage MTB11 or MTB15 reader (required reader interface RS-485)
No-Tour capable
Flexible connectivity options: manage with ENGAGE web and mobile apps or with one of our PACS providers
Inputs: door position (DPS), request to exit (REX), request to enter (REN), remote release (REL)
Outputs: lock relay, alarm relay, auxiliary (Aux) relay
Input Power: 12 or 24 VDC or Power over Ethernet (PoE/PoE+)
Provides DC output power and dry control contacts
More Information Specifications
Users: Up to 5,000
Audits: Up to 2,000
Schedules: Up to 16
Holidays: Up to 32
Time zones: Up to 16
Communication standards:
Bluetooth® Low Energy (version 4.2)
2.4 GHz Wi-Fi® (IEEE 802.11b/g/n)
WPA2, WPA, WEP, 802.1x (PEAP)
Transport Layer Security (TLS) version 1.2
Advanced Encryption Standard (AES), 256-bit
Gateway communication range:
Up to 30' in typical building environments. A detailed site survey is recommended.
Reference ENGAGE™ Gateway data sheet for additional details.
Connectivity options:
Mobile (send updates at door)
Wi-Fi access point (automatic daily updates)
ENGAGE Gateway, IP to host (Networked wireless reader interface)
No-Tour 1
Power inputs:
12 or 24 VDC at 3 amps input for powered outputs to get Max 2 amp output on relays, 0.5 amp minimum input when using dry contacts.
PoE/PoE+ (IEEE 802.3af/at)
Powered outputs: Locking mechanism, alarm, aux:
12 VDC input: 2A @ 12 VDC max (combined output across powered outputs)
24 VDC input: 2A @ 24 VDC max (combined output across powered outputs)
PoE input: 0.5A @ 12 VDC max (combined output across powered outputs)
PoE+ input: 1.5A @ 12 VDC max (combined output across powered outputs)
Dry outputs: locking mechanism, alarm, aux: Locking mechanism: 2A @ 30 VDC max
Reader interface:
0.3A @ 12 VDC Max (up to 500 ft.)
12 or 24 VDC input: 12V @ 0.3A max output POE or POE+ input: 12V @ 0.3A max output
Aux: 2A @ 30 VDC max
Alarm: 2A @ 30 VDC max
Reader (Schlage MTB11 or MTB15) (Required to utilize -485 interface)
Signal inputs:
Request-to-Enter (REN)
Request-to-Exit (REX)
Remote Release (REL) — wired
Door Position Switch (DPS)
Tamper (TAMP)
Operating temperature (indoor): -31°F (-35°C) to 151°F (66°C)
Operating humidity: 0 - 100% Non-condensing
Certifications: UL 294 Indoor, FCC Part 15, NEMA Enclosure Indoor (Type 1, 4, and 4X), ULC S319 Indoor, RoHS
Dimensions: 2.96" x 5.89" x 7.86"