Transit time is determined by shipping method and destination. Most orders will ship via FedEx or UPS Ground. If an item is out of stock or will require significant lead time we will contact you. Same-Day shipping cutoff time is 12:00 pm EST. Please see our Shipping Info page for more details. You can also CHAT WITH US to determine Shipping Estimates for your specific Items
Designed mainly for retrofit work, and are applied to the exposed surfaces of the door and frame.
Special hinge reinforcements are not required. Hollow metal door and frame manufacturer's standard is acceptable. Removal of hinge reinforcements in the door and frame is not advised.
Weight-bearing (per BHMA standard ANSI/BHMA A156.26-2006) for standard models: 83″ = 14 bearings, door weight = 280 lbs
10 fasteners required for each leaf
Standard duty hinge: 6" bearing spacing
Width: 1 1/4” (frame side – leaf)
Width: 1 3/8” (door side – leaf)
Cap Width: 25/32”
Height: 29/32” (total height of hinge)
Length: 83″
Certifications:
Certified to ANSI/BHMA A156.26-2017, Grade 1-300
Tested and certified by Underwriters Laboratories Inc. (USA and Canada) to UL10C
Certified up to a 3-Hour A-Label fire listing for all 4' 0" x 10' 0" (single) and 8' 0" x 10' 0" (pair) door and frame assemblies. Special FirePins required on 3-hour (A-label) assemblies.
Fire listing certifications apply to all approved hollow metal and wood door assemblies in drywall on masonry construction
Some door and frame conditions may require an extra 1/32" - 1/16" of clearance. Excessive clearance on fire-rated assemblies may violate the requirements for NFPA 80